Catéteres venosos periféricos innecesarios en la zona ambulatoria de un servicio de urgencias

  1. Ballesteros-Peña, S. 1
  2. Unanue-Arza, S. 1
  3. Juaristi, M.N. 2
  1. 1 Biocruces Bizkaia Health Research Institute. Barakaldo. España.
  2. 2 Osakidetza. Hospital de Basurto. Bilbao. España.
Journal:
Anales del sistema sanitario de Navarra

ISSN: 1137-6627

Year of publication: 2022

Volume: 45

Issue: 2

Pages: 2-2

Type: Article

DOI: 10.23938/ASSN.0998 DIALNET GOOGLE SCHOLAR lock_openOpen access editor

More publications in: Anales del sistema sanitario de Navarra

Abstract

The aim of this study was to estimate the frequency of unnecessary peripheral venous catheter (PVC) cannulation in adult patients attended in Ambulatory Emergency Care, and to analyse potential associated factors. An exploratory cross-sectional study was conducted in a tertiary hospital for two consecutive months. The proportion of canulated and unused PVC was calculated and related to patient variables. A PVC was cannulated in 701 patients. In 103 cases (14.7%; 95%CI: 12.1-17.3) the catheter was not used, and the patients were discharged directly home. Age over 64 was associated with a higher proportion of unsuitability (19.3% vs. 10.8%; p=0.002). There seems to be a certain proportion of catheters cannulated unnecessarily in Ambulatory Emergency Care, which would justify the implementation of good practice programmes in the assessment and selection of vascular accesses.

Bibliographic References

  • Citas 1. Thomas C, Cabilan CJ, Johnston ANB. Peripheral intravenous cannula insertion and use in a tertiary hospital emergency department: a cross-sectional study. Australas Emerg Care. 2020;23:166-172. https://doi.org/10.1016/j.auec.2020.02.001
  • Fry M, Romero B, Berry A. Utility of peripheral intravenous cannulae inserted in one tertiary referral emergency department: A medical record audit. Australas Emerg Nurs J. 2016;19:20-5. https://doi.org/10.1016/j.aenj.2015.10.003
  • Zurro Hernández J, de Santiago-Juárez López JA. Indicadores de calidad. Madrid: Sanidad y Ediciones, 2002.
  • Ballesteros-Peña S, Vallejo-De la Hoz G, Fernández-Aedo I. Pain scores for intravenous cannulation and arterial blood gas test among emergency department patients. Enferm Clin 2018;28:359-364. https://doi.org/10.1016/j.enfcli.2017.11.002
  • Gledstone-Brown L, McHugh D. Idle 'just-in-case' peripheral intravenous cannulas in the emergency department: is something wrong? Emerg Med Australas. 2018;30:309-326. https://doi.org/10.1111/1742-6723.12877
  • Robles-García M, Ceballos B, Rodríguez-Lera MJ, Piedra L, Sánchez-Ortiz S, Botero K. Factores asociados a la adecuación de la utilización de vías venosas en el servicio de urgencias. Rev Calidad Asistencial 2004;19:83-87. https://doi.org/10.1016/S1134-282X(04)77676-9
  • Ramos Sánchez MR, Fernández Núñez JM, Fernández García MT, Gómez-Valadés Casado AM, Caballero Paredes MI, Sánchez Sánchez MJ. Adecuación de la vía venosa periférica en un servicio de urgencias. Emergencias 2006;18:326-32.
  • Evison H, Sweeny A, Ranse J, Carrington M, Marsh N, Byrnes J, et al. Idle peripheral intravenous cannulation: an observational cohort study of pre-hospital and emergency department practices. Scand J Trauma Resusc Emerg Med. 2021;29:126. https://doi.org/10.1186/s13049-021-00941-y
  • Kelly AM, Egerton-Warburton D. When is peripheral intravenous catheter insertion indicated in the emergency department? Emerg Med Australas. 2014;26:515-516. https://doi.org/10.1111/1742-6723.12282
  • Lim ZJ, Nagle D, McAllan F, Ramanan R, Dendle C, Stuart RL, Egerton-Warburton D. Evaluating the sustained effectiveness of a multimodal intervention aimed at influencing PIVC insertion practices in the emergency department. Emerg Med J. 2020;37:444-449. https://doi.org/10.1136/emermed-2019-208852
  • Hawkins T, Greenslade JH, Suna J, Williams J, Rickard CM, Jensen M, et al. Peripheral Intravenous Cannula Insertion and Use in the Emergency Department: An Intervention Study. Acad Emerg Med. 2018;25:26-32. https://doi.org/10.1111/acem.13335
  • Egerton-Warburton D, McAllan F, Ramanan R, Lim ZJ, Nagle D, Dendle C, et al. Human factor-designed multimodal intervention reduces the rate of unused peripheral intravenous cannula insertion. Emerg Med Australas. 2019;31:372-7. https://doi.org/10.1111/1742-6723.13165